Last edited by Samuzil
Monday, May 18, 2020 | History

3 edition of Zweymüller total hip prosthesis found in the catalog.

Zweymüller total hip prosthesis

15 years" experience

by Wiener Symposium (3rd 1994)

  • 223 Want to read
  • 4 Currently reading

Published by Hogrefe & Huber in Seattle, Toronto .
Written in English

    Subjects:
  • Artificial hip joints -- Congresses.,
  • Total hip replacement -- Congresses.

  • Edition Notes

    Statement3rd Vienna Symposium ; Karl Zweymüller, editor.
    ContributionsZweymüller, K.
    The Physical Object
    Paginationix, 229 p. :
    Number of Pages229
    ID Numbers
    Open LibraryOL21047330M
    ISBN 100889371911

    Linear radiolucencies were frequently observed in Gruen-Zone 1 and 7, in 5 cases extending into zone 2 and 6 without influence on the clinical function of the implant. Conclusion: Material and geometry of the Zweymüller total hip lead to a load transfer through the threads of the cup. The integration of the stem relies on cortical interlocking. Mar 10,  · Introduction: The need for better durability and longevity in total hip arthroplasty for patients with various hip joint diseases remains a challenge. This study aimed to obtain medium-term results at a follow-up of >10 years for Zweymüller-Plus total hip arthroplasty with ceramic-on-polyethylene bearing.

    1. Introduction. Periprosthetic bone loss, i.e., a decrease in bone mineral density (BMD) around an implant, is a major concern following total hip arthroplasty (THA) [1, 2].Severe periprosthetic bone loss may contribute to aseptic loosening of the prosthesis or the risk of periprosthetic fracture [] and presents serious problems if revision surgery becomes necessary [].Author: Yutaka Inaba, Hiroyuki Ike, Masatoshi Oba, Tomoyuki Saito. Abstract: We previously reported the 10 to year follow-up results for total hip replacements with the Zweymüller Alloclassic stem and a threaded cup in 94 patients. The present study is a clinical and radiographic outcome update after a minimum follow-up of 25 years. Four patients (4 hips) were lost and 46 patients (50 hips) died, leaving 44 patients (50 hips) available for follow-up.

    Zweymuller Total Hip Prosthesis: 15 Years' Experience Hardcover – Dec 31 by Zweymuller (Author) See all formats and editions Hide other formats and editions. Amazon Price New from Used from Hardcover "Please retry" Author: Zweymuller. In the present study, we report the histological features of cases of ALTR from a large, diverse group of hip implants that includes three major classes: metal-on-metal (MoM) hip resurfacing arthroplasty (HRA), MoM large head total hip arthroplasty (THA), and non-MoM THA with cobalt/chrome (CoCr) dual modular innovationoptimiser.com by:


Share this book
You might also like
Fort Worth is cooking!

Fort Worth is cooking!

Report on the use of Kodak mammographic daylight film handling system for breast radiography in a breast screening centre

Report on the use of Kodak mammographic daylight film handling system for breast radiography in a breast screening centre

FCE listening and speaking skills

FCE listening and speaking skills

An act for preventing tumults and riotous assemblies, and for the more speedy and effectual punishing the rioters.

An act for preventing tumults and riotous assemblies, and for the more speedy and effectual punishing the rioters.

PH Ref Gd&1key Bb Pkg (6th Edition)

PH Ref Gd&1key Bb Pkg (6th Edition)

Contract and mercantile law

Contract and mercantile law

history of the negotiation of the ambassadors sent to the Duke of Savoy

history of the negotiation of the ambassadors sent to the Duke of Savoy

Low Cost Aircraft Flutter Clearance.

Low Cost Aircraft Flutter Clearance.

Life-saving appliances on steamers.

Life-saving appliances on steamers.

personality of Britain

personality of Britain

Atmospheric numerical modeling resource enhancement and model convective parameterization/scale interaction studies, reporting period, October 6, 1987 - December 31, 1993

Atmospheric numerical modeling resource enhancement and model convective parameterization/scale interaction studies, reporting period, October 6, 1987 - December 31, 1993

Glass craft

Glass craft

Zweymüller total hip prosthesis by Wiener Symposium (3rd 1994) Download PDF EPUB FB2

Jan 01,  · Sixty-eight young patients (74 prostheses), mean age 43 years (standard deviation ) at the time of the index operation, with a Zweymüller cementless total hip prosthesis were evaluated with a mean follow-up time of 75 months (SD ).

At follow-up, the mean Harris Hip Score was 94 (SD ).Cited by: 3. the original Alloclassic Zweymüller Stem, making this prosthesis represents a milestone in the treatment of total joint replacement.

4 SL O Stem, Step Less Offset Total hip arthroplasty in February with use of an Alloclassic Zweymüller SL Stem (size 4).

Mar 29,  · Essentials in Total Hip Arthroplasty by Dr. Javad Parvizi is a succinct, yet comprehensive text that provides a unique and colorful look into the world of total hip arthroplasty, an in-depth history of this common procedure, as well as strategies to treat and prevent complications/5(3).

Aug 18,  · Get Hip. How to Prepare for and Recover from Total Hip Replacement [Rob Taylor, Wayne Moschetti] on innovationoptimiser.com *FREE* shipping on qualifying offers. Get Hip.

tells the story of hip replacement, from the first pains of osteoarthritis, through medical decisions/5(19). Zweymüller cementless total hip arthroplasty with a threaded titanium cup and rectangular femoral stem has been available in the Netherlands since the early s.

The aim of our study was to evaluate the clinical and radiological results of the Zweymüller total hip prosthesis in patients with a follow-up of at least 10 innovationoptimiser.com by: Cementless primary total hip replacement - Four to eight year results with the Zweymuller-Alloclassic (R) prosthesis Article (PDF Available) in International Orthopaedics 22(1) · February.

InViennese orthopaedic surgeon Prof. Karl Zweymüller introduced a type of hip joint prosthesis which allowed for cementless implant Performance of the Zweymüller total hip arthroplasty system: a literature review including arthroplasty register data | innovationoptimiser.com Sinceovertotal hip arthroplasties have used the original Alloclassic ® Zweymüller ® Hip Stem, making this uncemented prosthesis one of the most widely implanted in the world.

The straightforward surgical technique and the broad product range are designed to aid surgeons in their goal of providing optimum care for their patients.

Feb 29,  · We found 26 different stems from different companies producing or having produced in the past the Zweymüller-type femoral stems for hip prosthesis. Accurate preoperative identification of the Zweymüller femoral stem type may be of critical importance to Cited by: 3.

Basic concepts of total joint arthroplasty. Hip and Knee Replacement pre-op planning, post-op protocols, and discussion of implants and complications. Hip & Knee Book. Cover KNEE CHAPTERS. BASIC CONCEPTS OF TKA TKA TECHNIQUES KNEE IMPLANTS basics of arthroplasty textbook.

HIP AND KNEE BOOK. Performance of the Zweymüller total hip arthroplasty system: A literature review including arthroplasty register data Article · May with Reads How we measure 'reads'. Delaunay C, Kapandji A () Primary total hip arthroplasty with the Zweymüller first-generation cementless prosthesis.

A 5- to 9-year retrospective study. J Cited by: 7. The incidence of total hip arthroplasty is increasing in number because of successful outcomes. Although technically challenging, once mastered a hip replacement is one of the most gratifying surgeries for both patient and surgeon.

This book covers some of the most important aspects of hip replacement surgery. These include preoperative planning, anesthesia, classification systems, management Author: Vaibhav Bagaria. Jul 05,  · Primary stability of a shoulderless Zweymüller hip stem: a comparative in vitro micromotion study Cementless as well as cemented total hip arthroplasty (THA) demonstrated long-term survival rates after 15 years of over 90 %.

The Zweymüller-type prosthesis is a clinically proven straight stem locking in the distal metaphysis and Cited by: 3. 72 works Search for books with subject Total hip replacement.

Search. Total hip replacement Malcolm I. Jayson Read. Hip replacement Richard N. Villar Read. Read. Read. Read. Read. 20 years of Zweymüller hip endoprosthesis Wiener Symposium (4th ) Read. Borrow. Orthopaedic knowledge updateHip Prosthesis, Accessible book, Protected.

Original Article Contamination of surfaces for osseointegration of cementless total hip implants by small aluminium oxide particles: analysis of established implants by use of a new technique Alexander Kolb, [email protected] Manuel Sabeti-Aschraf, Reinhard Windhager, Department of Orthopedics, Medical University of Vienna, Währinger Gürtel, Vienna, Austria Department of Cited by: 1.

SL-PLUS Indications. SL-PLUS Stem is intended for advanced hip joint wear due to degenerative, post-traumatic or rheumatoid arthritis, fracture or avascular necrosis of the femoral head.

The SL-PLUS Stems are for uncemented use only. The devices are intended to aid the surgeon in relieving the patient of hip pain and restoring hip motion.

IMPLANT ATLAS Hip & Knee Book. Cover KNEE CHAPTERS. BASIC CONCEPTS OF TKA TKA TECHNIQUES KNEE IMPLANTS KNEE X-RAYS TKA COMPLICATIONS Normal hip angle versus varus and valgus hip, and clinical correlates.

Dorr Classification and impact on implant selection The authors, world renowned experts in the field, present practical, clinical information from their extensive experience in the treatment of these total revision hip surgery.

Topics covered include: bending fractures of the metaphysis, shearing fractures of the joint surface, compression fractures of the joint surface, avulsion fractures, radio-carpal fracture and dislocation, combined. Total hip arthroplasty using rectangular Zweymueller-stems has proven successful years results.

The surface is routinely roughened by grit-blasting. Inevitably, some Al2O3 remains on the surface, which might lead to earlier loosening and less osteointegration. Hence, a special process was developed to remove the Al2O3. We hypothesized that. [13] Zweymüller K.

20 years of Zweymüller hip endoprosthesis Hans Huber Verlag ISBN pp [14] Müller DA, Zingg P, Dora C. 5 year survival and radiological outcome of minimally invasive total hip replacements using a relatively new implant (Quadra/Versafitcup, Medacta, Switzerland).

SGO22thth June, Lausanne.The Preserve stem is a modified Zweymüller femoral stem that omits the trochanteric wing.

Omission of the trochanteric wing of the prosthesis might influence its rotational stability, but, there are no reports about the rotational stability of a modified Zweymüller femoral stem.

The purpose of this study was to investigate the effect of the trochanteric wing on rotational stability by Author: Tomonori Shigemura, Takanori Omae, Shigeru Mitsuhashi, Yasuaki Murata, Yohei Yamamoto, Takashi Sato.Total Hip Replacement Patient Guide Th is guide is for you and your family to use before, during and after your (prosthetic hip joint) pelvis femur damaged hip joint replaced hip joint books, magazines, crossword puzzles, music and handiwork • Small battery-operated equipment (shaver, radio, etc.) is acceptable, but electrical.